If you are building a new home in Southwest Florida, one of the first hurricane decisions you will face is how to protect the windows and glass doors. The two main choices are impact-resistant windows and doors, or standard windows with hurricane shutters. Both can meet the Florida Building Code when they are properly rated and installed, but they work very differently day to day. This guide explains what the code requires, how Lee, Charlotte and Collier counties fit in, how to read product approvals, how insurance mitigation credits work, and the trade-offs of each option. It is general information, not engineering or insurance advice.
What the Florida Building Code Requires
Which code edition applies
Florida has one statewide building code. The 8th Edition (2023) Florida Building Code took effect on December 31, 2023. The Florida Building Commission’s schedule lists December 31, 2026 as the effective date for the 9th Edition (2026). In general, the edition that applies to your home depends on when it is permitted, so ask your builder which edition your plans are designed to.
Wind-borne debris regions
During a hurricane, wind picks up roof tiles, branches and other debris and throws it at buildings. If a window breaks, wind and rain rush in, raising pressure inside the house and causing major water damage. For that reason, the code requires extra protection for openings in wind-borne debris regions.
Under the 8th Edition as amended, a wind-borne debris region is an area within the hurricane-prone region that is either:
- Within 1 mile of the coastal mean high water line where the ultimate design wind speed is 130 mph or greater, or
- Anywhere the ultimate design wind speed is 140 mph or greater
What protection is required
FEMA summarizes the Florida Building Code, Residential this way: glazed openings in wind-borne debris regions must be impact-resistant or protected with an impact-protective device such as a shutter. “Glazed openings” means windows, skylights and doors with glass.
The code sets a minimum, and some owners choose more protection than it requires.
How Lee, Charlotte and Collier Fit
Whether a specific lot is in a wind-borne debris region depends on its design wind speed and, for the 130 mph rule, its distance from the coast. The state’s design wind speed maps are drawn as contour lines, and the University of Florida GeoPlan Center prepared local wind speed line maps for building jurisdictions under the 2023 code.
In practice, the answer comes from the building department that will issue your permit. That might be a city such as Cape Coral, Punta Gorda or Naples, or the county for unincorporated land in Lee, Charlotte or Collier. Your builder’s design professional will list the design wind speed, exposure category and debris-region status on the plans.
Miami-Dade and Broward counties have additional “High-Velocity Hurricane Zone” provisions. Those generally do not apply in Southwest Florida, but you will see the term on many product labels and approvals.
Option 1: Impact-Resistant Windows and Doors
Impact windows use glazing designed to stay in place when struck. FEMA explains that laminated glass is made of two or more panes with a plastic interlayer. The glass may break when hit by debris, but the interlayer stays intact and keeps wind and rain out. FEMA also notes that laminated glazing may improve a building’s energy efficiency.
Advantages
- Always in place. There is nothing to install when a storm is coming, which matters if you travel, are away for the summer, or can’t safely put up shutters.
- No storage space needed for panels or hardware.
- No added work at upper-floor windows.
Trade-offs
- A struck window may crack even though it did its job, and then need replacement.
- The windows, frames and installation all have to be rated for your site’s wind pressures, not just for impact.
- Cost varies widely by product, size, frame material and number of openings. Get itemized quotes rather than relying on rules of thumb.
Option 2: Hurricane Shutters Over Standard Windows
Shutters protect the glass from the outside. FEMA’s guidance shows several common types, including roll-up (roll-down), accordion, Bahama and colonial shutters, and removable storm panels.
Advantages
- Can be combined with standard windows that are rated for wind pressure but not impact.
- Some types, such as accordion and roll-down shutters, stay mounted on the house, so there are no loose panels to store.
- Closed shutters add a physical layer over the glass.
Trade-offs
- Shutters are “active” protection. FEMA notes that they must be installed or closed before the storm, so there has to be enough time and someone available to do it. Upper levels may need ladders or other equipment.
- If shutters aren’t closed, the windows aren’t protected.
- Removable panels need storage and organized hardware.
- FEMA advises installing only shutters labeled as tested and code compliant, and anchoring them properly so they don’t become debris themselves.
The code also contains a limited option for precut wood structural panels on certain low-rise homes. It comes with specific conditions, so ask your building official before relying on plywood.
Don’t Forget Doors, Garage Doors and Skylights
Opening protection is about every opening, not just windows. FEMA points out that garage doors are often the largest opening in a home and can be blown in, pulled out or twisted off their tracks. FEMA recommends garage doors tested to industry wind-load standards (ANSI/DASMA 108), and notes that impact-rated garage doors can be tested under DASMA 115. Entry doors with glass, sliding glass doors and skylights also need to be addressed in the plan.
Product Approvals: Florida Product Approval and Miami-Dade NOAs
Windows, doors, shutters and garage doors used in Florida generally need product approval. Under section 553.842 of the Florida Statutes, the Florida Building Commission runs a statewide product evaluation and approval system. Approved products get a Florida Product Approval number (an “FL number”), which you can look up on the Commission’s website by manufacturer or number and by code version.
The same statute lists the Miami-Dade County Product Control Division among approved evaluation entities. Miami-Dade issues its own approvals, known as Notices of Acceptance (NOAs), which you can search on the county’s Product Control website.
When you review a product approval, check:
- That the approval matches the exact product and model
- The size limits and the design pressure ratings, compared with what your plans require
- Whether it is approved for impact (wind-borne debris) protection
- The installation instructions and anchoring details, which are part of the approval
FEMA also recommends checking product labels. Windows and sliding doors carry a Performance Grade (PG) rating that should equal or exceed the required design pressure.
Insurance: Wind Mitigation Credits and Form OIR-B1-1802
Florida law (section 627.0629) requires residential property insurers to include actuarially reasonable discounts, credits or other rate differentials for construction features shown to reduce windstorm losses. Opening protection and window, door and skylight strength are on the list. Each insurer must post information about its hurricane mitigation discounts on its website, and must notify policyholders of the available discount ranges when a policy is issued and at renewal (section 627.711).
Insurers use a uniform form to verify mitigation features, the Uniform Mitigation Verification Inspection Form, OIR-B1-1802. According to Citizens Property Insurance Corporation, a revised version (Rev. 04/26) took effect April 1, 2026, and opening protection is among the updated features. Citizens said the revisions would not change the credits available at that time.
Under section 627.711, insurers must accept the form when it is signed by certain qualified inspectors, including licensed home inspectors with the required hurricane mitigation training, certified building code inspectors, licensed general, building or residential contractors, professional engineers and architects.
Because discounts vary by insurer, we don’t quote percentages here. Before you choose, ask your insurance agent how each option would be credited on your policy, and keep product approvals, permits and invoices so an inspector can verify what was installed.
Questions to Ask Your Builder
- Is the lot in a wind-borne debris region, and what design wind speed and pressures apply?
- Which code edition will the permit fall under?
- Which openings will use impact glazing, and which, if any, will use shutters?
- What are the product approval numbers for each window, door, garage door and shutter?
- How will shutters be stored, deployed and maintained?
- Will the finished home be documented for a wind mitigation inspection?
Our guides to building for hurricanes in Florida and home insurance for new construction go deeper on related topics.
Building a New Home in Southwest Florida?
Proudhouse Builders designs and builds homes in Southwest Florida, and we are happy to walk through opening protection options for your plan. Call us at (239) 321-0594 or send a message through our contact page. You bring the land, we do the rest.
Sources
- Florida Building Commission, Building Code Information System home page (8th Edition effective December 31, 2023): floridabuilding.org/c/default.aspx
- Florida Building Commission, 9th Edition (2026) FBC Code Update Development Tasks, workplan for October 2026 meeting (effective date 12/31/2026): floridabuilding.org/fbc/commission/FBC_1026/Commission/Workp…
- Florida Building Commission, FBC Supplement, Annual Technical Amendment, 8th Edition (2023), wind-borne debris region definition: floridabuilding.org/fbc/commission/FBC_0424/Commission/2023_…
- FEMA, Hurricane Michael in Florida Recovery Advisory 2, “Best Practices for Minimizing Wind and Water Infiltration Damage” (June 2019) (opening protection requirement, testing and labeling, garage door standard, PG ratings): fema.gov/sites/default/files/2020-07/best-practices-minimize…
- FEMA, Hurricane and Flood Mitigation Handbook for Public Facilities, Fact Sheet 3.2: Wall Systems and Openings (March 2022) (laminated glazing, shutter types and deployment, garage doors, DASMA 115): fema.gov/sites/default/files/documents/fema_p-2181-fact-shee…
- University of Florida GeoPlan Center, Wind Speed Line Maps for the 2023 Florida Building Code: geoplan.ufl.edu/wind-speed
- Florida Statutes §553.842 (product evaluation and approval), 2026: flsenate.gov/Laws/Statutes/2026/553.842
- Florida Building Commission, Product Approval search: floridabuilding.org/pr/pr_app_srch.aspx
- Miami-Dade County, Product Control Search: miamidade.gov/building/pc-search_app.asp
- Florida Statutes §627.0629 (residential property insurance; mitigation discounts), 2026: flsenate.gov/Laws/Statutes/2026/627.0629
- Florida Statutes §627.711 (notice of mitigation discounts; uniform mitigation verification inspection form), 2026: flsenate.gov/Laws/Statutes/2026/627.711
- Citizens Property Insurance Corporation, “Uniform Mitigation Verification Inspection Form Changes” (March 19, 2026): citizensfla.com/-/20260319-uniform-mitigation-verification-i…
Own land in Southwest Florida?
Our team can tell you what your parcel can become. Call (239) 321-0594 or start a land review online.
Start a land review